TURBINE OIL PURIFICATION SYSTEM & FILTER MACHINE · 600–18,000 LPH

Turbine Oil Purifier & Purification System: Break Emulsions ≤ 100 ppm, Hold NAS 5 & Cut Varnish MPC ≤ 8

Stop steam-seal water emulsification, oil foaming, sticky governor servo valves, and bearing pad temperature spikes across steam turbines, CCGT gas turbines, hydro governors, and turbo-compressors (ISO VG 32 / 46) — continuous online kidney-loop systems across WJJ Heating-Free Coalescing (≤ 100 ppm), WVDJ 3-in-1 Varnish & Water (MPC ≤ 8), and WZJC Vacuum Dehydration & Degassing (≤ 50–100 ppm).

24/7 Online Bypass
Zero Turbine Shutdown · Auto Drain & Safety Interlocks
≤ 50–100 ppm / NAS 5
Breaks Steam-Seal Emulsions & 0.1 μm Wear Silt
MPC ≤ 8 (Lab 1.1–4.5)
Clears Soluble Varnish · Stops Servo Valve Sticking
600–18,000 LPH
380V–480V (50/60Hz) & Ex d IIC / IP56 Turbine Decks
SOLUTIONS & MACHINE SERIES · SYMPTOM-MATCHED SKIDS

Match Your Turbine Oil Contamination to the Right Purification System

Steam-seal water leaks, dissolved varnish causing servo-valve stiction, and entrained-air foaming require different separation physics. Each card below pairs the exact turbine symptom with its matching purification system, verified lab targets (ppm, NAS, MPC), viscosity (32–100 cSt, up to ≤ 220 cSt), and operating limits.

SYMPTOM 01 · STEAM SEAL LEAKS & EMULSIFIED WATER
Milky Oil / Heavy Water (< 10% in) → Cut ≤ 100 ppm & < NAS 5
0.9–7.6 kW heating-free bulk dewatering · Auto water drain
HEATING-FREE COALESCING · WJJ-10 TO WJJ-300
WJJ heating-free coalescing-separating balanced charge turbine oil purifier

WJJ Coalescing & Balanced-Charge Purifier

100% cellulose-free synthetic coalescing stages paired with 0.1 μm + / − balanced-charge agglomeration rapidly break free/emulsified water and remove abrasive wear silt without electric heaters.

Flow Rate: 600–18,000 LPH (10–300 L/min)
Water: ≤ 100 ppm (< 10% inlet)
Cleanliness: < NAS 5 (NAS 3–7 · 0.1 μm)
Power / Temp: 0.9–7.6 kW (No Heaters · ≤ 80°C)
Best Fit: Steam turbines with gland-seal steam leaks, CCGT 6–20+ m³ reservoirs, centrifugal compressors (32–100 cSt, up to ≤ 220 cSt), 500+ hrs unattended duty.
Boundary: Cannot adsorb hot dissolved varnish (use WVDJ for high MPC) or strip sub-50 ppm dissolved gas (use WZJC); requires demulsible oil.
Evaluate WJJ for Your Conditions
SYMPTOM 02 · SERVO STICKING, VARNISH & PAD TEMP SPIKES
High MPC (> 15–30) / Bearing Hot Spots → Pull MPC ≤ 8 & ≤ 100 ppm
0.02 μm electrostatic + Dow resin · Reverse-dissolves baked deposits
3-IN-1 VARNISH, WATER & SLUDGE · WVDJ-20 / IIC
WVDJ 3-in-1 turbine oil varnish and water removal purifier with electrostatic field and Dow resin

WVDJ Varnish & Water Removal System

Combines 0.02 μm circular electrostatic collection, selective Dow ion-exchange resin, and synthetic coalescing to strip dissolved & suspended varnish, reverse-dissolve baked deposits from bearings and servo valves online, and hold moisture ≤ 100 ppm without halting the turbine.

Flow Rate: 1,200 LPH (20 L/min, ≤ 80,000 L)
Varnish Target: MPC ≤ 8 (Dow Resin)
Sludge / Water: 0.02 μm (NAS ≤ 6) · ≤ 100 ppm
Power / Ex: 1.2 kW · IP55 / Ex d IIC IP56
Best Fit: Gas turbines, newly commissioned trains, syngas/ethylene/air-separation compressors (VG 32/46), Ex-zones (WVDJ-20-IIC) where moisture > 100 ppm (< 10%) meets varnish.
Boundary: Pre-dewater severe 10–30 m³ seal floods with WJJ to protect resin life. For strictly dry oil (≤ 100 ppm, zero bottom water), dry-only WVD is available.
Evaluate WVDJ for Your Conditions
SYMPTOM 03 · OIL FOAMING, ENTRAINED AIR & DISSOLVED WATER
Foaming / Governor Lag / Dissolved Moisture → Cut ≤ 50–100 ppm
−0.06 to −0.09 MPa vacuum degassing · Auto defoaming & ≤ 3 μm
VACUUM DEHYDRATION & DEGASSING · WZJC 2KY–12KY
WZJC single-stage vacuum turbine oil filter machine for dissolved water and gas stripping

WZJC Single-Stage Vacuum Filter Machine

Flashes off dissolved moisture, free water, and entrained air inside a coarse-atomization vacuum chamber with automatic defoaming control, low heat-flux (≤ 2 W/cm²) heating, and ≤ 3 μm pleated elements to stop foaming and governor instability.

Flow Rate: 1,800–12,000 LPH (30–200 L/min)
Water / Gas: ≤ 50–100 ppm + Air Stripping
Vacuum / Heat: −0.06 to −0.09 MPa (~60°C, ≤ 80°C)
Heater / Solids: ≤ 2 W/cm² (21–81 kW) · ≤ 3 μm (NAS 7)
Best Fit: Auxiliary turbines, governor hydraulics, marine gear/turbine sumps (≤ 220 cSt) needing air stripping & deep moisture removal; KY / BF / BY / KF frames.
Boundary: ≥ 3 μm mechanical elements & vacuum cannot remove dissolved varnish or 0.02–0.5 μm gels (use WVDJ); heavy water without 21–81 kW power uses WJJ.
Evaluate WZJC for Your Conditions
FACTORY DATASHEET QUICK-CHECK · 600–18,000 LPH

Core WJJ Frame Specifications, WVDJ / WZJC Specs & Plant Power Compatibility

Request Custom Frame & Flow Sheet →
Specification (WJJ Series) WJJ-30 WJJ-50 WJJ-100 (Core Utility) WJJ-200 WJJ-300
Flow Capacity (LPH / L/min) 1,800 LPH (30) 3,000 LPH (50) 6,000 LPH (100) 12,000 LPH (200) 18,000 LPH (300)
Total Power (Heating-Free) 0.9 kW 1.8 kW 3.5 kW 6.5 kW 7.6 kW
Outlet Water / Cleanliness ≤ 100 ppm moisture (from < 10% inlet water) · NAS Class 3–7 (sustains < NAS 5) · 0.1 μm precision · ≤ 80°C, 0.05–0.4 MPa
Dimensions (L × W × H mm) 1,820 × 1,000 × 1,650 1,855 × 1,000 × 1,650 1,890 × 1,000 × 1,675 2,335 × 1,180 × 1,780 2,335 × 1,200 × 1,900
Weight / Typical Fit 530 kg (also WJJ-10: 600 LPH / 500 kg) 560 kg · Medium turbines 780 kg · 6–20 m³ units (also WJJ-80/150) 1,000 kg · Utility turbines 1,150 kg · Central stations
Companion WVDJ & WZJC Specs:
WVDJ-20 / WVDJ-20-IIC: 1,200 LPH (20 L/min), 1.2 kW, 20–80°C, −0.06 MPa inlet / 0.4 MPa outlet, 2,175 × 915 × 1,875 mm, 550 kg (IP55) / 650 kg (IP56 Ex d IIC) · MPC ≤ 8, NAS ≤ 6.
WZJC (2KY–12KY): 1,800 / 3,000 / 6,000 / 9,000 / 12,000 LPH (30–200 L/min), 21–81 kW, −0.06 to −0.09 MPa, ≤ 3 μm (NAS 7), ≤ 50–100 ppm water.
3-Phase Grids, Hazardous Zones & Frames:
Custom-wired to plant auxiliary supply: 380V 50Hz / 60Hz, 400V 50Hz, 415V 50Hz, 440V/220V 60Hz, and 480V 60Hz. Available with CE compliance, Ex d IIC / IP56 explosion-proof housings, KY/BF/BY/KF frames, and optional online moisture/particle sensors.
PROVEN FIELD RESULTS & LAB BENCHMARKS · STEAM, GAS & COMPRESSOR SITES

Verified Turbine Oil Field Results & Documented Plant Installations

Documented turbine and rotating-machinery deployments verified against factory engineering logs and third-party lab reports — cutting moisture below 100 ppm, stabilizing NAS ≤ 5–6, and dropping bearing pad temperatures & MPC varnish potential.

Proven Across Leading Power & Process Sites: China Guodian CNOOC Sinopec PetroChina Linde Gas Wanhua Chemical CITIC Pacific Power
Two VIFLUTER WJJ-100 coalescing balanced charge turbine oil purifiers operating on a GE gas turbine lube reservoir
GAS TURBINE COGENERATION · 2× WJJ-100

China Guodian GE Gas Turbine (20 m³ GE PG61111FA)

Total ISO VG 32 turbine oil failed pre-commissioning limits (617 ppm water, NAS ≥ 11); two heating-free WJJ-100 skids restored Moisture < 100 ppm and NAS ≤ 5 without heater stress.

Measured: 617 ppm → < 100 ppm · NAS ≥ 11 → ≤ 5
Petrochemical cracked gas compressor and offshore gas turbine electrostatic plus Dow resin varnish removal
TURBO-COMPRESSOR & OFFSHORE TURBINE · WVDJ

Cracked Gas Compressor & Offshore Gas Turbine

Dropped petrochemical cracked-gas compressor bearing pad temperature from 115°C to 89°C online; on a Solar T60 offshore gas turbine (1,800 L Regal R&O 46), third-party testing verified MPC ΔE 31.5 → 4.4 and NAS 13 → 5, stabilizing control-valve pressure.

Measured: Pad 115°C → 89°C · MPC 31.5 → 4.4 · NAS 13 → 5
VIFLUTER vacuum dehydration turbine oil filter machine at CITIC Pacific Power plant
POWER PLANT DEHYDRATION · WZJC / WJJ-100

CITIC Pacific Power & 75 MW Condensing Steam Turbine

WZJC Single-Stage Vacuum removes 100% free water and up to 95% dissolved water/gas (≤ 50–100 ppm, ≤ 3 μm) on continuous power-plant duty; on a 75 MW condensing steam turbine with > 2% chronic gland-seal water (ISO VG 46), WJJ-100 held moisture ≤ 100 ppm and NAS 5–6.

Measured: Gland Water > 2% → ≤ 100 ppm · NAS 5–6
Verified Turbine Oil Conditioning Benchmarks (ASTM D6304 / NAS 1638 / ASTM D7843):
Outlet Water (ASTM D6304)
≤ 50–100 ppm
Particulate Cleanliness
NAS 5–6 (3–5 WJJ)
Varnish Potential (MPC ΔE)
MPC ≤ 8 (Lab 1.1–4.5)
Online Kidney-Loop Duty
Zero Shutdown (24/7)

Want sizing benchmarks or reference specs for your turbine train? Share your turbine type, tank volume, and current water ppm / MPC / NAS report for technical evaluation.

Submit Conditions for Reference Cases
TURBINE DECK RELIABILITY & UNATTENDED SAFETY

Engineered for Continuous Online Turbine Oil Conditioning Without Forced Outages

Water ingress from steam gland seals, invisible dissolved varnish precipitating during cooldown, and entrained air foam trigger sticky servo valves, bearing hot spots, and costly full oil flushes. VIFLUTER builds dedicated offline kidney-loop skids tailored specifically to steam turbines, gas turbines, hydro governors, and centrifugal turbo-compressors.

Steam Power Plants CCGT Gas Turbines Hydro Governor Oils Turbo-Compressors

Unattended Online Protection & Auto-Controls

Plumbs into an independent offline kidney-loop bypass on reservoir drain/return ports — leaving main turbine lube pressure, flow, and power generation completely undisturbed (500+ hrs unattended duty on WJJ).

Equipped with automatic water drainage (WJJ), automatic defoaming, liquid-level and ≤ 80°C low heat-flux control (WZJC, ≤ 2 W/cm²), plus earth-leakage, phase-loss, lid-interlock, and overpressure shutdown protection with leak-free hydraulic ball-valve fittings.

Turbine Deck Power, Ex d IIC & Desaturation Sizing

Built to your plant utility and hazardous-area deck rules: 380V 50/60Hz, 400V/415V 50Hz, 440V/220V 60Hz, 480V 60Hz, CE compliance, Ex d IIC / IP56 explosion-proof builds (WVDJ-20-IIC & custom Ex cabinets), and KY/BF/BY/KF frames.

Sized for 6–20 m³ turbine tanks (WJJ-50/100, 3,000–6,000 LPH), up to 12,000 LPH vacuum dehydration/degassing (WZJC), or continuous varnish desaturation up to 80,000 L (WVDJ-20) to avoid full oil replacement and chemical flushes.

Need Ex d IIC enclosure, custom 380V–480V wiring, or kidney-loop LPH sizing?
Send oil grade (VG 32/46), tank volume, and current lab values to our pre-sales technical department.
BUYER FAQ · CLEAR TECHNICAL ANSWERS

Key Engineering & Purchasing Questions Before You Specify

Clear engineering answers on coalescing vs. vacuum dehydration, invisible varnish & cold-startup servo sticking, WVDJ vs. WVD water limits, target ppm / NAS / MPC values, foaming control, and Ex-zone power builds.

Should I choose a WJJ coalescing turbine oil purifier or a WZJC vacuum turbine oil filter machine for water and foaming control?

Choose the heating-free WJJ coalescing balanced-charge unit (0.9–7.6 kW, 600–18,000 LPH) when steam-seal or cooler leaks introduce heavy free and emulsified water (< 10% inlet) into demulsible 32# or 46# turbine oil — it separates and drains bulk water rapidly via an automatic water drain, cuts outlet water to ≤ 100 ppm, and holds < NAS 5 cleanliness without heaters. Choose the WZJC vacuum filter machine (−0.06 to −0.09 MPa, 21–81 kW) with automatic defoaming control when entrained air, severe oil foaming, or sub-100 ppm (≤ 50 ppm) dissolved moisture causes governor instability.

Why cannot standard 3-micron filters, centrifuges, or vacuum purifiers stop turbine oil varnish?

During turbine operation at 40–60°C, polar oxidation byproducts remain dissolved in solution, and nascent colloids sit in the 0.02–0.5 μm sub-micron range. Conventional 3–10 μm mechanical cartridges, centrifugal separators, and heater-type vacuum purifiers cannot capture dissolved varnish molecules or sub-micron gels, causing cartridge blinding while MPC rises. Removing both soluble and suspended varnish requires selective Dow ion-exchange resin paired with 0.02 μm electrostatic collection (WVDJ).

What is the moisture boundary between WVDJ (3-in-1) and dry-only WVD varnish removal units?

Dry electrostatic-resin WVD units have zero dewatering capability: they strictly require dry oil (≤ 100 ppm operating limit, ceiling < 500 ppm with zero free water settled at the tank bottom), otherwise water saturates the resin and triggers electrostatic leakage-current shutdowns. Whenever turbine moisture exceeds 100 ppm (up to < 10%) or water ingress coexists with varnish risk, specify WVDJ-20, which adds a full-synthetic coalescing-separator stage to maintain ≤ 100 ppm water alongside MPC ≤ 8.

Why can NAS particle counts look normal while bearing pad temperatures spike or servo valves stick during startup?

Optical particle counters only measure solid particles ≥ 4 μm(c), whereas dissolved varnish precursors and early sub-micron gels (< 0.5 μm) remain invisible while the turbine runs hot (40–60°C) — then drop out during cooldown or turning-gear cycles to coat tight-clearance servo valves and thrust-bearing pads, driving temperatures to 105–120°C and risking fail-to-start trips. Continuous online desaturation with WVDJ (0.02 μm electrostatic collection + selective Dow ion-exchange resin) pulls MPC ≤ 8 and gradually re-dissolves legacy deposits without a costly full oil drain and flush.

What target water, NAS cleanliness, and MPC metrics should a turbine oil system maintain, and how do I size flow rate (LPH)?

Under turbine oil standards (GB/T 7596-2017 / ASTM D6304 / ASTM D7843), operating benchmarks are ≤ 100 ppm water (≤ 50–100 ppm outlet capability), NAS 5–6 cleanliness (ISO ≤ −/16/13; ceiling ≤ NAS 8), MPC ΔE ≤ 15 (preferred ≤ 8; > 30 critical), demulsibility ≤ 30 min at 54°C (GB/T 7305), and acid number ≤ 0.2–0.35 mgKOH/g (ASTM D664). For 6–20 m³ reservoirs, plants typically specify WJJ-50 (3,000 LPH) or WJJ-100 (6,000 LPH); for continuous varnish control up to 80,000 L, specify WVDJ-20 (1,200 LPH).

Can systems run online in kidney-loop mode without shutdown, and are Ex d IIC & 380V–480V (50/60Hz) builds available?

Yes. WJJ, WVDJ, and WZJC all operate in an independent off-line (kidney-loop) bypass circuit plumbed to reservoir drain/return ports without affecting main turbine lube pressure or halting generation (500+ hrs unattended continuous runtime on WJJ with earth-leakage, phase-loss, lid-interlock, and overpressure protection). WVDJ-20-IIC is rated IP56 with Ex d IIC enclosures, and WJJ / WZJC builds support custom Ex-proof cabinets, enclosed weatherproof housings (BF/BY), and 380V 50/60Hz, 400V/415V 50Hz, 440V/220V 60Hz, and 480V 60Hz grids. Always sample from the active bottom drain rather than stagnant level-gauge dead legs.

PRE-SALES TECHNICAL DEPARTMENT

Direct to Our Pre-Sales Technical Department

Every inquiry submitted here goes directly to our pre-sales technical department. Engineers review your turbine operating conditions and oil lab profile first before recommending WJJ, WVDJ, or WZJC.

TECHNICAL EVALUATION
01 · Operating Conditions & Contamination Profile — Turbine or compressor type, oil grade (ISO VG 32 / 46), and current water ppm, NAS cleanliness, or MPC varnish reading (sampled from the active bottom drain).
02 · Flow Sizing, Grid & Ex-Zone Matching — Tank volume (m³ or L), online kidney-loop vs. outage turnover, plant power (380V–480V, 50/60Hz), and Ex d IIC requirements.
The more complete your project details, the more accurate our technical evaluation and solution will be.
Submit Project Parameters
Fields marked with * are required.
Country code + local number (auto-detected by IP when available).
© VIFLUTER · Jiangsu Vifluter Resource Recycling Technology Co., Ltd.
Technical Support WhatsApp: +86-180-1378-4821