TRANSFORMER OIL PURIFICATION PLANT & FILTRATION SYSTEM · 540–12,000 LPH

Transformer Oil Purifier & Purification Machine: Restore ≥ 70 kV Dielectric Strength & ≤ 5 ppm Moisture

Fix failed BDV tests, extract winding-trapped moisture via hot-oil circulation, and eliminate dissolved gas without oil scorching across 66 kV–500 kV substations, transformer OEMs, and EPC commissioning sites — compare WZJA Double-Stage High Vacuum (≤ 5 Pa), WZJC Single-Stage Vacuum, and WJYJ 3-Stage New-Oil Filter Carts.

≥ 70 kV / ≤ 5 ppm
IEC 60422 & IEEE C57.106 Targets (≤ 0.3% Gas)
≤ 5 Pa Roots Vacuum
Double-Stage WZJA for 66–500 kV & High Altitude
4-in-1 Field Modes
Vacuum Drying, Filling, Hot-Oil Circulation & Degassing
540–12,000 LPH
380V–440V (50/60Hz), Trailers & Weatherproof Builds
SOLUTIONS & EQUIPMENT SERIES · VOLTAGE-MATCHED PLANTS

Match Your Voltage Class & Field Duty to the Right Purification System

A 220 kV substation commissioning job, an auxiliary industrial oil budget, and sea-freighted drums of new insulating oil require completely different vacuum and filtration physics. Each card below pairs the exact transformer scenario directly with its matching machine, lab targets, and strict operating boundaries.

APPLICATION 01 · 66 kV–500 kV HV/EHV & COMMISSIONING
Low BDV (< 50 kV) / Wet Windings → Restore ≥ 70 kV & ≤ 5 ppm
≤ 5 Pa Roots double-stage vacuum · Drying, filling & hot-oil circulation
FLAGSHIP HIGH VACUUM PLANT · WZJA-3KY TO WZJA-12KY
WZJA double-stage vacuum transformer oil purifier with Roots booster pump

WZJA Double-Stage Vacuum Transformer Oil Purifier

Pairs a high-speed Roots booster with a rotary backing stage, thin-film flash degassing, automated infrared foam/level control (zero pump oil carryover), VFD + PID flow balancing, and anti-acetylene constant-temperature heating (35–65°C) for utility commissioning.

Flow Rate: 3,000–12,000 LPH (50–200 L/min)
Dielectric / Water: ≥ 70 kV BDV · ≤ 5 ppm
Vacuum / Gas: ≤ 50 Pa work (≤ 5 Pa ult.) · ≤ 0.3%
Heat / Filtration: 35–65°C Anti-C2H2 · ≤ 1 μm (NAS 6)
Best Fit: 66–500 kV substation power transformers, instrument transformers, transformer OEMs, EPC commissioning (including high-altitude sites) needing 4-in-1 vacuum drying, under-vacuum filling, hot-oil circulation, and oil extraction.
Boundary: Draws 40–140 kW (3-phase) and requires tight flanges/hoses for ≤ 5 Pa. Never use vacuum degassing alone to mask rising DGA acetylene (C2H2) — repair internal arcing faults first.
Evaluate WZJA for Your Voltage Class
APPLICATION 02 · PLANT AUXILIARY & NON-HV MINERAL OILS
Bulk Moisture & Particle Budgets → Cut ≤ 50–100 ppm & ≤ 3 μm
−0.06 to −0.09 MPa single-stage (JB/T 5285 C-series) · Lower kW & CapEx
SINGLE-STAGE VACUUM PURIFIER · WZJC-2KY TO WZJC-12KY
WZJC single-stage vacuum oil purifier for industrial plant oil dehydration

WZJC Single-Stage Vacuum Oil Purifier

Under JB/T 5285 convention, C-series single-stage vacuum skids dehydrate industrial lubrication, hydraulic, turbine, and non-critical auxiliary mineral oils via −0.06 to −0.09 MPa vacuum, staged thermostatic heating (~60°C, ≤ 80°C), and ≤ 3 μm pleated elements.

Flow Rate: 2,000–12,000 LPH (30–200 L/min)
Water Target: ≤ 50–100 ppm (Multi-Pass)
Vacuum / Heat: −0.06 to −0.09 MPa (~60°C, ≤ 80°C)
Power / Solids: 21–81 kW · ≤ 3 μm (NAS 7)
Best Fit: Industrial plant utility oil stations and non-critical auxiliary mineral-oil moisture budgets where lower connected kW and compact single-stage operation are prioritized.
Boundary: Not a substitute for WZJA when HV/EHV transformer specs mandate ≤ 5 ppm, ≤ 0.3% gas, ≥ 70 kV BDV, or vacuum oil filling. Never share hoses/units across dirty industrial or OLTC oil and main HV tanks without flushing.
Evaluate WZJC for Your Plant Oils
APPLICATION 03 · DRUM TRANSFER, TOP-UPS & PRE-FILTRATION
Dirty Drummed New Oil (NAS 10–11) → Polish to NAS 7 & Save 1 μm Filters
0.6–3 kW plug-and-run · 100 + 5 + 3 μm (β ≥ 200) · Optional water-absorbing
NEW OIL TRANSFER & PRE-FILTRATION CART · WJYJ-10 TO WJYJ-100
WJYJ 3-stage portable precision oil filter cart for new oil filling and drum-to-tank transfer

WJYJ 3-Stage Precision Oil Filter Cart

Replaces open buckets when moving new mineral oil from sea-freighted drums or IBC totes, stripping rust scale and transport grit (≤ 200 cSt) via 3-stage graded cartridges so costly 1 μm elements inside WZJA vacuum plants do not clog prematurely.

Flow Rate: 540–6,000 LPH (9–100 L/min)
Filtration: 100 + 5 + 3 μm (β ≥ 200)
Cleanliness: NAS 10–11 → NAS 7 (Single Pass)
Power / Weight: 0.6–3 kW (No Heaters) · 150–260 kg
Best Fit: Drum-to-tank new mineral oil filling, substation yard top-ups, and upstream pre-cleaning of rusty/particulate-heavy oil before WZJA vacuum processing (optional water-absorbing & Ex-proof cartridges).
Boundary: Mechanical filtration cart only (no vacuum chamber or heater) — cannot degas dissolved air, evacuate transformer tanks, or strip dissolved water down to ≤ 5 ppm. Confirm cartridge compatibility for ester/synthetic fluids.
Evaluate WJYJ for Drum Transfer
PURIFICATION PLANT SIZING & ELECTRICAL SPECS · 540–12,000 LPH

Standard WZJA Double-Stage Plant Sizes (LPH), Companion Specs & Substation Grids

Request Custom LPH & Voltage Build →
Specification (WZJA Series) WZJA-3KY WZJA-6KY (Core Utility Size) WZJA-9KY WZJA-12KY
Flow Capacity (LPH / L/min) 3,000 LPH (50 L/min) 6,000 LPH (100 L/min) 9,000 LPH (150 L/min) 12,000 LPH (200 L/min)
Heating / Total Power 30 kW / 40 kW 60 kW / 70 kW 90 kW / 105 kW 120 kW / 140 kW
Vacuum Rating (Double-Stage) Working vacuum ≤ 50 Pa · Ultimate vacuum ≤ 5 Pa (Roots booster + backing stage)
Oil Temp & Working Pressure 35–65°C adjustable (anti-acetylene constant-temperature heating) · Working pressure ≤ 0.5 MPa
Dimensions (L × W × H mm) 2,150 × 1,260 × 1,980 2,350 × 1,570 × 2,200 2,350 × 1,650 × 2,500 2,600 × 2,300 × 1,900
Best-Fit Duty Scope 35–110 kV small substations & industrial transformers 110–220 kV utility maintenance & mobile service contractors 220–330 kV hub substations & transformer assembly plants 500 kV EHV banks & bulk new-oil terminals (custom up to 30,000 LPH)
Multi-Voltage Grid Builds & Outdoor Substation Readiness:
Wired at the factory to match your substation auxiliary supply: 380V 50Hz / 60Hz, 400V 50Hz, 415V 50Hz, and 440V/220V 60Hz grids worldwide. Integrated VFD + PID speed control with optional sealed weatherproof canopies and highway-towable trailers.
Companion WZJC & WJYJ Capacities:
WZJC Single-Stage: 2,000 / 3,500 / 6,000 / 9,000 / 12,000 LPH (30–200 L/min, 21–81 kW) for plant/auxiliary moisture budgets.
WJYJ Filter Cart: 540 / 1,080 / 1,800 / 3,000 / 6,000 LPH (9–100 L/min, 0.6–3 kW) for drum transfer & pre-cleaning.
VERIFIED FIELD CASES & TEST BENCHMARKS · UTILITY, POWER & OEM SITES

Proven Oil Test Outcomes Across Utility, Power & Fleet Operations

Inspect verified field deployments from VIFLUTER project records — covering high-voltage insulating oil restoration to ≥ 70 kV BDV and ≤ 5 ppm moisture, power generation unit dehydration, and 3-stage new mineral oil transfer filtration.

Proven Across Leading Utility & Heavy Industry Sites: NORINCO Petrochemical China Guodian PetroChina Sinopec CNOOC CITIC Pacific Special Steel HBIS
VIFLUTER WZJA double-stage vacuum insulating oil purifier case for NORINCO
INSULATING OIL · WZJA DOUBLE-STAGE VACUUM

NORINCO / Panjin Insulating Oil Project (≤ 500 kV Conditioning)

Heavy-duty double-stage high vacuum deployment (WZJA-500 / custom large-flow VFD up to 500 L/min, ≤ 1 μm fine filtration, ≤ 5 Pa ultimate vacuum) with PLC anti-acetylene heating for ≤ 500 kV insulating oil conditioning toward utility targets (≥ 70 kV BDV, ≤ 5 ppm water, ≤ 0.3% gas, NAS Class 6).

Target Spec: ≤ 500 kV · ≥ 70 kV BDV · ≤ 5 ppm · ≤ 0.3% Gas
VIFLUTER oil purification system deployed for China Guodian Huzhou Nanxun 2x100 MW GE 6F power plant
POWER GENERATION · 2×100 MW GE 6F

China Guodian Huzhou Nanxun Power Plant (20 m³ Reservoir)

In utility service at China Guodian’s 2×100 MW GE 6F combined-cycle plant (20 m³ oil reservoir), two WJJ-100 skids cleared pre-commissioning moisture & particles down to < 100 ppm and < NAS 5. For auxiliary plant mineral-oil moisture budgets (non-HV dielectric), WZJC Single-Stage supports multi-pass dehydration down toward ≤ 50–100 ppm.

Measured: Moisture < 100 ppm · Cleanliness < NAS 5
VIFLUTER WJYJ portable 3-stage filter cart purifying mineral oil during fleet transfer
NEW OIL & FLEET TRANSFER · WJYJ-30 / WJYJ-20

Automotive OEM Plant (3-Stage Drum Transfer)

Multiple WJYJ-30 & WJYJ-20 filter carts maintain Grade 46 & 68 mineral oil cleanliness during drum filling and maintenance transfer. Graded 100 + 5 + 3 μm (β ≥ 200) stages polish raw NAS 10–11 drummed oil down to NAS 7 before it touches a vacuum purifier or main tank.

Measured: Raw Drum Oil NAS 10–11 → NAS 7 (Single Pass)
WZJA Insulating Oil Conditioning Targets (≤ 5 Pa Ultimate Vacuum & ≤ 1 μm Filtration):
Dielectric Strength (BDV)
≥ 70 kV
Moisture Content
≤ 5 ppm
Total Dissolved Gas
≤ 0.3%
Particulate Cleanliness
NAS Class 6

Need commissioning LPH calculations or substation reference specs? Share your transformer kV class, oil volume, and current BDV / ppm test values.

Submit Voltage Class & Volume for Reference Cases
SUBSTATION COMMISSIONING & TRANSFORMER PROTECTION

Built for 66 kV–500 kV Substation Commissioning, Vacuum Drying & Safe Site Operation

Failing a commissioning BDV test, watching moisture rebound from wet cellulose windings, or triggering vacuum pump oil carryover stalls substation energization. VIFLUTER builds 4-in-1 double-stage high-vacuum plants engineered specifically for HV/EHV utilities, transformer OEMs, EPC commissioning crews, and rewind workshops.

66–500 kV Substation EPCs Transformer OEMs Rewind Workshops ≤ 35 kV Plant Substations

Anti-Acetylene Heating & Zero-Carryover Safeguards

Multi-group constant-temperature anti-acetylene heating (35–65°C) prevents localized thermal oil cracking, new C2H2 generation, and elevated tan δ during hot-oil circulation.

Automated infrared foam and liquid-level control prevents pump oil carryover into Roots/backing stages, backed by VFD + PID stepless flow balancing and interlocked pressure, phase-sequence, and overload shutdown protection.

4-in-1 Field Modes, Outage Sizing & Substation Builds

Executes transformer vacuum drying, under-vacuum oil filling, closed-loop hot-oil circulation, and oil extraction in one skid — sized via LPH = Oil Volume × (3–5 Passes) ÷ Outage Window (e.g., WZJA-6KY at 6,000 LPH completes 3 passes on a 20,000 L 110–220 kV bank in 10 hrs).

Factory-wired to 380V 50/60Hz, 400V/415V 50Hz, or 440V/220V 60Hz substation supply, with optional highway-towable trailers, sealed weatherproof canopies for dusty/humid switchyards, PLC automation, and high-altitude Roots stability.

Need substation LPH outage sizing, trailer build, or custom V/Hz wiring?
Send voltage class (kV), tank oil liters, and grid voltage to our pre-sales technical department.
BUYER FAQ · CLEAR TECHNICAL ANSWERS

Key Engineering & Purchasing Questions Before You Specify

Clear engineering answers on double-stage vs. single-stage vacuum, outage LPH sizing, hot-oil circulation & vacuum filling, DGA acetylene limits, OLTC / new-drum isolation, and substation power builds.

What is the difference between Double-Stage (WZJA) and Single-Stage (WZJC) vacuum oil purifiers for transformers?

A double-stage vacuum transformer oil purifier (WZJA) adds a high-speed Roots booster pump ahead of the rotary backing stage to reach ≤ 50 Pa working (≤ 5 Pa ultimate) vacuum, restoring ≥ 70 kV BDV, ≤ 5 ppm moisture, and ≤ 0.3% gas on HV/EHV transformers up to 500 kV. Under the JB/T 5285 convention, single-stage WZJC (−0.06 to −0.09 MPa) is built for plant lubrication, hydraulic, and auxiliary mineral oils (≤ 50–100 ppm multi-pass) where HV dielectric commissioning targets are not mandated.

How do I size LPH flow capacity (3,000–12,000 LPH) for a 35 kV, 110 kV, or 220–500 kV substation outage window?

Use Plant LPH = Oil Volume (L) × (3–5 Passes) ÷ Outage Window (Hours). For example, a 20,000 L 110 kV / 220 kV bank completing 3 full passes in 10 hours requires 6,000 LPH (WZJA-6KY, 100 L/min), while a 2,500 L 35 kV substation transformer targeting ≥ 70 kV BDV fits WZJA-3KY (3,000 LPH). Standard WZJA models run 3,000–12,000 LPH (with custom large-flow builds up to 30,000 LPH for 500 kV hubs).

Can WZJA perform transformer vacuum drying, under-vacuum oil filling, and hot-oil circulation to pull moisture from windings?

Yes. Unlike simple mechanical filter carts, WZJA integrates 4 field modes on one skid: transformer vacuum evacuation/drying, simultaneous under-vacuum oil filling (eliminating winding micro-bubbles), closed-loop hot-oil circulation (35–65°C) to pull moisture out of solid cellulose insulation without post-run ppm rebound, and standalone oil extraction.

Can a transformer oil purification machine fix rising acetylene (C2H2) in DGA tests, or scorch oil during heating?

First, WZJA uses multi-group constant-temperature anti-acetylene heating (35–65°C, ≤ 0.5 MPa) interlocked with oil flow so the purifier itself never scorches oil, creates new C2H2, or raises tan δ. Second, no purifier can repair an active internal fault: if DGA already shows rising acetylene from internal winding or tap-changer arcing, diagnose and fix the fault before degassing and refilling.

Why pre-filter drummed new oil with WJYJ before vacuum treatment, and how should OLTC / dirty industrial oils be isolated?

Sea-freighted steel drums and outdoor storage accumulate bottom rust scale and condensation (often reading NAS 10–11). Running drummed oil (≤ 200 cSt) through a WJYJ 3-stage filter cart (100 + 5 + 3 μm, β ≥ 200) achieves NAS 7 first so fine ≤ 1 μm vacuum elements inside WZJA never blind prematurely. For cross-contamination safety, never switch hoses or skids from carbon-heavy OLTC diverter compartments or industrial lube sumps into main HV tanks without dedicated hoses, full draining, flushing, and fresh elements.

Can systems be built for 380V–440V (50/60Hz) substation grids, high-altitude sites, weatherproof canopies, or road trailers?

Yes. Every skid is wired prior to dispatch to match your substation power (380V 50/60Hz, 400V 50Hz, 415V 50Hz, and 440V/220V 60Hz three-phase). WZJA’s Roots booster maintains deep vacuum stability on high-altitude substations, and units can be delivered with sealed weatherproof canopies for dusty or humid switchyards, highway-towable road trailers, VFD + PID control, PLC automation, and explosion-proof cabinets.

PRE-SALES TECHNICAL DEPARTMENT

Direct to Our Pre-Sales Technical Department

Every inquiry submitted here goes directly to our pre-sales technical department. Engineers review your transformer voltage class, oil volume, and lab readings first before sizing WZJA, WZJC, or WJYJ.

TECHNICAL EVALUATION
01 · Voltage Class & Dielectric Profile — Transformer rating (kV), oil volume (L), current BDV (kV), bottom-drain moisture (ppm), and DGA status.
02 · Outage Window, Site Power & Mobility — Target LPH / 3–5 passes outage hours, substation supply (380V–440V, 50/60Hz), vacuum drying/filling mode, and trailer or weatherproof canopy needs.
The more complete your project details, the more accurate our technical evaluation and solution will be.
Submit Project Parameters