INDUSTRIAL VACUUM & COALESCING OIL PURIFIERS · 10–300 L/MIN (2.6–79 GPM)

Vacuum Dehydration Oil Purification System: Remove Free, Emulsified & Dissolved Water Down to ≤ 50–100 ppm

Engineered for hydraulic reservoirs, steam & gas turbine lube systems, heavy industrial gearboxes, and ≤ 500 kV power transformers — factory-configured across WZJC Single-Stage, WZJA Double-Stage (≤ 5 Pa), WJZ Balanced-Charge, and WJJ Heating-Free Coalescing.

253+ Installations
Power, Petrochemical, Steel & Substation Sites
≤ 5 Pa / ≥ 70 kV
Double-Stage High Vacuum (≤ 5 ppm H₂O, WZJA)
10–300 L/min
Modular Capacities (2.6–79 GPM Across 4 Series)
380V–480V Custom
50Hz / 60Hz, Ex-Proof, PLC & Trailer Builds
SOLUTIONS & MACHINE SERIES · ZERO OVER-SPECIFYING

Match Your Oil Contamination to the Right Purification System

No single water-removal unit fits every viscosity, water state, or target kV. Compare our four factory-built series below — including exact operating limits — or send your tank volume and oil grade directly for sizing.

Milky Hydraulic / Gear Oil
Need ≤ 50–100 ppm & ≤ 3 µm
ISO VG 32–220 / 75W-90 → WZJC Single-Stage
≤ 500 kV Transformer Oil
Need ≥ 70 kV BDV & ≤ 5 ppm
≤ 5 Pa high vacuum + Roots → WZJA Double-Stage
Water + Sub-Micron Sludge
Need < NAS 5 & ≤ 100 ppm
Vacuum + / − electrostatic → WJZ Balanced-Charge
Heavy Free Water / Low kW
> 500–1,000+ ppm Seal Leaks
0.9–7.6 kW, zero heating → WJJ Coalescing
SINGLE-STAGE VACUUM · WZJC-2KY TO WZJC-12KY
WZJC single-stage vacuum dehydration oil purification system for hydraulic, gear, and turbine oil

WZJC Vacuum Dehydration System

Industrial workhorse for removing free, emulsified, and dissolved water plus entrained gases from milky hydraulic, turbine, and heavy gear oils without scorching additives.

Flow Rate: 30–200 L/min (8–53 GPM)
Water Target: ≤ 50–100 ppm
Vacuum: −0.06 to −0.09 MPa
Heating / Solids: ~60°C (≤ 80°C) · ≤ 3 µm
Best Fit: Shield tunneling hydraulics, steel mills, paper machines, marine & industrial gearboxes across ISO VG 32–220 / 75W-90.
Boundary: Not built for 110–500 kV substation dielectric targets (≤ 5 ppm / ≥ 70 kV BDV) — choose WZJA for transformer oil.
Evaluate WZJC for Your Conditions
DOUBLE-STAGE HIGH VACUUM · WZJA-3KY TO WZJA-12KY
WZJA double-stage high vacuum oil purifier with Roots booster for transformer and insulating oil

WZJA High Vacuum Transformer Purifier

Pairs a Roots booster with a rotary-vane backing stage, thin-film degassing, infrared foam/level control, VFD+PID balancing, and anti-acetylene heating.

Flow Rate: 3,000–12,000 L/h (13–53 GPM)
BDV / Water: ≥ 70 kV · ≤ 5 ppm
Vacuum: ≤ 50 Pa work (≤ 5 Pa ult.)
Gas / Heat: ≤ 0.3% · 35–65°C · ≤ 1 µm
Best Fit: Substations & EHV transformers up to 500 kV, vacuum oil filling, transformer vacuum drying, and hot-oil circulation.
Boundary: Over-specified for hydraulic/lube sumps needing only ≤ 100 ppm; requires leak-tight metallic/fluoropolymer hoses and no un-flushed oil cross-sharing.
Evaluate WZJA for Your Conditions
VACUUM + BALANCED CHARGE · WJZ-30 TO WJZ-200
WJZ vacuum balanced charge oil purifier combining flash dehydration and electrostatic sub-micron filtration

WJZ Vacuum + Balanced-Charge Purifier

Combines vacuum flash dehydration with dual-path + / − electrostatic agglomeration so sub-micron silt, oxide sludge, and varnish precursors cluster and trap cleanly.

Flow Rate: 30–200 L/min (8–53 GPM)
Cleanliness: < NAS Class 5 · ≤ 100 ppm
Vacuum: −0.06 to −0.09 MPa (~60°C)
Max Pressure: Up to 0.6 MPa
Best Fit: Precision forging presses, TBMs, hydraulic pump/motor test benches, railway bogie & coal-mining gearbox flushing lines with dark, sludged oil.
Boundary: Requires non-conductive mineral/synthetic hydrocarbon oil — not for conductive water-glycol (HFC) or phosphate-ester EHC fluid.
Evaluate WJZ for Your Conditions
HEATING-FREE COALESCING · WJJ SERIES
WJJ coalescing separation and balanced charge oil purifier for heating-free water and particle removal

WJJ Coalescing Balanced-Charge Purifier

Two-stage coalescing-separation plus electrostatic agglomeration strips bulk free and mechanically emulsified water without vacuum pumps or heaters.

Flow Rate: 10–300 L/min (2.6–79 GPM)
Cleanliness: NAS 3–7 (< NAS 5) · ≤ 100 ppm
Power Draw: 0.9–7.6 kW (No Heaters)
Thermal Stress: Zero Additive Stress
Best Fit: Steam & combined-cycle turbine reservoirs with gland steam leaks, diesel/ISO VG 32–68 hydraulics facing heavy free-water slugs (> 500–1,000+ ppm).
Boundary: Cannot remove truly dissolved water (< 20 ppm) or dissolved gases, tight surfactant chemical emulsions, or oils > ISO VG 150 at ambient temp.
Evaluate WJJ for Your Conditions
PROVEN FIELD RESULTS · 253+ DOCUMENTED INSTALLATIONS

Verified Field Results & Documented Industrial Installations

Field systems operating across power generation, petrochemical complexes, steel rolling mills, tunneling hydraulics, and substations — with verified before-and-after moisture and NAS cleanliness results.

Trusted by Leading Industrial Sites: China Guodian PetroChina Sinopec CNOOC CITIC Pacific Special Steel HBIS NORINCO Refining
WZJA double-stage high vacuum transformer oil purifier skid at industrial insulating oil facility
≤ 500 kV Insulating Oil · WZJA-500 Double-Stage

Petrochemical Insulating-Oil Refinery (NORINCO)

Heavy-duty double-stage high vacuum (Roots + backing stage) with anti-acetylene constant-temperature heating for ≤ 500 kV transformer oil degassing and deep dehydration to utility targets.

Target Duty: ≤ 500 kV Class · Deep Degassing & Dehydration
WJZ-50 vacuum balanced charge oil purifier treating emulsified hydraulic test oil
Heavy Machinery Hydraulics · WJZ-50 (Repeat Order 2017)

Large Precision Machinery Manufacturer

Heavily emulsified, particle-laden hydraulic & tunneling test-bench oil restored by WJZ-50 — validated by a repeat unit order in 2017.

Measured: NAS > 12 → < NAS 7 · Moisture < 100 ppm
Two WJJ-100 coalescing balanced charge oil purifiers operating on 2x100 MW GE 6F gas turbine lube systems
2×100 MW GE 6F Combined Cycle · 2× WJJ-100

China Guodian Huzhou Nanxun Power Plant

Pre-commissioning moisture and particle contamination in a 20 m³ Total 32# turbine tank treated by two heating-free WJJ-100 units.

Measured: Moisture < 100 ppm · Cleanliness < NAS 5

Want reference specs or sizing benchmarks for your oil grade? Share your equipment type, tank capacity, and current ppm / kV status for a technical evaluation.

Submit Conditions for Reference Cases
MANUFACTURING STRENGTH & PLANT-READY DELIVERY

Direct Engineering Manufacturer: Verified Factory Testing & Plant-Ready Builds

Built in Jiangsu, China, every VIFLUTER system is engineered around your oil grade, reservoir volume, and plant utility — eliminating middleman markups, wrong vacuum sizing, and site power mismatches.

Transformers & Power Substations Steam Turbines & Power Plants Steel Mills & Heavy Hydraulics Tunneling, Marine & Gearboxes

Factory Pre-Shipment Verification

Every unit undergoes vacuum tightness testing, VFD+PID flow balancing, and dielectric interlock testing prior to shipment from our Jiangsu plant.

Heated units use staged thermostatic control (~60°C, ≤ 80°C ceiling) or anti-acetylene 35–65°C heating to protect oil additives and transformer oil chemistry.

Engineer Sizing & Plant Grid Builds

Sized to complete 3–5 tank passes during outages or 1–2 passes/day on continuous bypass (21–140 kW vacuum; 0.9–7.6 kW WJJ).

Built to your plant grid (380V / 400V / 415V / 440V / 480V, 50/60Hz) with Ex-proof, weatherproof, PLC, and trailer/skid configurations.

Need custom voltage, Ex-proof enclosure, or tank turnover sizing?
Submit your tank volume and oil grade to our pre-sales technical department for evaluation.
BUYER FAQ · CLEAR TECHNICAL ANSWERS

Key Engineering & Purchasing Questions Before You Specify

Quick answers on single-stage vs. double-stage vacuum, coalescing alternatives, achievable ppm & kV targets, sizing, and plant power compatibility.

Single-stage vacuum vs. double-stage high vacuum oil purifier: what is the difference?

A single-stage vacuum purifier (WZJC / WJZ) operates at −0.06 to −0.09 MPa, ideal for hydraulic, turbine, and gear oils needing multi-pass free, emulsified, and dissolved water removal toward ≤ 50–100 ppm. A double-stage high vacuum purifier (WZJA) adds a Roots booster pump to pull ≤ 50 Pa working (≤ 5 Pa ultimate) vacuum — mandatory for high-voltage transformer insulating oil (≤ 500 kV) targeting ≤ 5 ppm moisture, ≤ 0.3% gas, and ≥ 70 kV breakdown voltage.

Vacuum dehydration vs. coalescing oil purifier (WJJ): which method should I choose?

Choose a vacuum dehydration system whenever you must strip dissolved water (below ~100 ppm), degas entrained air, break stubborn chemical emulsions, or dehydrate viscous oils above ISO VG 150. Choose WJJ coalescing separation when heavy free-water leaks (> 500–1,000+ ppm) dominate ISO VG 32–68 turbine or light hydraulic oil, target moisture is ≤ 100 ppm, and you want zero heaters with just 0.9–7.6 kW draw.

How low can vacuum dehydration bring water content (ppm) and breakdown voltage (kV)?

Industrial single-stage WZJC and WJZ units control free, emulsified, and dissolved water down toward ≤ 50–100 ppm through multi-pass circulation (while severe bulk free-water floods are stripped efficiently by WJJ first). For dielectric oil, double-stage high vacuum WZJA targets ≤ 5 ppm water, ≤ 0.3% gas content, and ≥ 70 kV breakdown voltage depending on initial oil condition and recirculation passes.

Will vacuum heating damage oil additives or generate acetylene?

WZJC/WJZ use staged thermostatic heating with interlocking temperature control (~60°C typical, ≤ 80°C ceiling), and WZJA uses anti-acetylene constant-temperature heating (35–65°C) specifically designed to avoid localized transformer oil cracking and acetylene generation. Unlike adsorbent clay/resin beds, vacuum + mechanical + balanced-charge processes do not strip oil-soluble AW/antioxidant additives.

How do I size flow rate (L/min, L/h, GPM) for my oil viscosity and tank volume?

Match skid flow (WZJC/WJZ: 30–200 L/min / 8–53 GPM; WZJA: 3,000–12,000 L/h / 13–53 GPM; WJJ: 10–300 L/min / 2.6–79 GPM) to complete 3 to 5 full tank passes during an outage (e.g., 50 L/min turns a 5,000 L tank every 100 minutes) or 1–2 passes/day on continuous online bypass. WZJC/WJZ cover ISO VG 32–220 / 75W-90; oils > VG 320 may require flow derating or custom pre-heating.

What power supply, explosion-proof, and fluid-compatibility limits apply?

Every skid is built to your plant grid: e.g., 480V 60Hz, 440V/220V 60Hz, 380V 60Hz, 415V 50Hz, or 380V/400V 50Hz, with Ex-proof cabinets, weatherproof enclosures, PLC, and trailer mounts on request. Vacuum skids draw 21–140 kW vs. 0.9–7.6 kW for WJJ. Never run conductive water-glycol (HFC) through vacuum dehydration or balanced-charge systems, and do not share mineral-oil units with phosphate-ester EHC fluids.

PRE-SALES TECHNICAL DEPARTMENT

Direct to Our Pre-Sales Technical Department

Every inquiry submitted here goes directly to our pre-sales technical department. Engineers review your operating conditions and technical feasibility first before recommending a purification process.

TECHNICAL EVALUATION
01 · Operating Conditions & Feasibility — Oil grade (ISO VG or insulating oil), water state, and fluid compatibility.
02 · Flow & Grid Matching — Tank turnover (3–5 passes or continuous bypass) and plant power (380V–480V, 50/60Hz).
The more complete your project details, the more accurate our technical evaluation and solution will be.
Submit Project Parameters
Fields marked with * are required.
Country code + local number (auto-detected by IP when available).
© VIFLUTER · Jiangsu Vifluter Resource Recycling Technology Co., Ltd.