WJL Balanced Charge Oil Purifier

VIFLUTER's high-precision balanced charge purification technology extends filtration capability to the sub-micron range, efficiently removing particulate contaminants from the fluid
PRODUCTS >
WJL Balanced Charge Oil Purifier
VIFLUTER FC Series vacuum heat pump evaporator for industrial wastewater treatment
WJL Balanced Charge Oil Purifier

请输入要描述的内容进行内容补充
Especially suitable for systems with stringent oil requirements and high levels of fine particles and oxidation sludge
请输入要描述的内容进行内容补充
Especially suitable for systems with rapid, heavy contamination ingress requiring fast reduction of contamination level
请输入要描述的内容进行内容补充
Insensitive to water content in the lubrication system
请输入要描述的内容进行内容补充
Low consumable cost and long element life; comparable to imported ones
High purification efficiency; can be used for dedicated online filtration or as a mobile unit rotating between multiple machines
请输入要描述的内容进行内容补充
Kidney-loop operation, small footprint, easy operation, intelligent monitoring without affecting main equipment
请输入要描述的内容进行内容补充
Unattended operation, low maintenance, low operating cost
DOWNLOAD BROCHURE

Product Features

Integrates progressive three-stage fine filtration with advanced Balanced Charge Agglomeration technology. It extends contaminant capture capability down to the sub-micron range, rapidly intercepting ultra-fine suspended particles and restoring oil cleanliness to stringent international standards (e.g., NAS 1638 / ISO 4406).
Sub-Micron Balanced Charge & Progressive 3-Stage Filtration
Integrates progressive three-stage fine filtration with advanced Balanced Charge Agglomeration technology. It extends contaminant capture capability down to the sub-micron range, rapidly intercepting ultra-fine suspended particles and restoring oil cleanliness to stringent international standards (e.g., NAS 1638 / ISO 4406).
Specifically targets and actively removes dissolved oxidation gums, soft contaminants, and varnish deposits that standard mechanical filters miss. It thoroughly eliminates sluggish movement and sticking in high-precision servo and proportional valve spools, deep-cleaning internal piping to restore full control responsiveness.
Varnish & Oxidation Gum Elimination to Prevent Valve Sticking
Specifically targets and actively removes dissolved oxidation gums, soft contaminants, and varnish deposits that standard mechanical filters miss. It thoroughly eliminates sluggish movement and sticking in high-precision servo and proportional valve spools, deep-cleaning internal piping to restore full control responsiveness.
Features an integrated intelligent monitoring interface that continuously tracks and displays critical operational metrics in real time: pre-filter pressure, collector pressure, high-voltage electrostatic field voltage, and leakage current. Provides instant diagnostics and element replacement alerts for maximum operational safety.
Real-Time Data Telemetry & Electrostatic Field Monitoring
Features an integrated intelligent monitoring interface that continuously tracks and displays critical operational metrics in real time: pre-filter pressure, collector pressure, high-voltage electrostatic field voltage, and leakage current. Provides instant diagnostics and element replacement alerts for maximum operational safety.
Employs a non-intrusive bypass "kidney-loop" circulation design, purifying reservoir fluid continuously without causing pressure drops or interfering with running host machinery. Delivers 24/7 unattended reliability, extended consumable lifespan, and low energy consumption, substantially slashing long-term maintenance expenditure.
Kidney-Loop Continuous Operation & Low Lifecycle Cost
Employs a non-intrusive bypass "kidney-loop" circulation design, purifying reservoir fluid continuously without causing pressure drops or interfering with running host machinery. Delivers 24/7 unattended reliability, extended consumable lifespan, and low energy consumption, substantially slashing long-term maintenance expenditure.

How It Works

Balanced Charge Agglomeration

Positive and negative electrodes are placed in two parallel flow paths through the non-conductive fluid, charging the particulate contaminants — one path with a positive (+) charge and the other with a negative (-) charge.


The oppositely charged particles are then remixed, attract each other and agglomerate into larger clusters, so that fine particles that are otherwise difficult to filter can be easily captured and removed.



Technical Specifications
ParameterUnitWJL-20WJL-30WJL-50WJL-75WJL-100WJL-150WJL-200
Flow RateL/min20305075110150200
Working PressureMPa≤0.5
Power SupplyVCustomized based on request (For example: USA 480V 60Hz, Mexico 440V/220V 60Hz, Saudi Arabia 380V 60Hz, Nigeria 415V 50Hz...)
Total PowerkW0.711.82.344.87
Inlet/Outlet
Pipe Size
mmDN20DN25DN32DN40DN40DN50Inlet DN65,
Outlet DN50
Weightkg195260270370400620870
Lengthmm1040138014051600170020002500
Widthmm530570570820820900900
Heightmm1200121512151400160016301700
Inlet/Outlet
Connection
——1CB-30-12WD
M30×2 for hose;
G3/4"×14 for ball valve
1CB-36-16WD
M36×2 for hose;
G1"×11 for ball valve
1CB-45-20WD
M45×2 for hose;
G1¼"×11 for ball valve
1CB-52-24WD M52×2 for hose;
G1½"×11 for ball valve
-- --
Customer Case Studies

Customer Background:A Wind Power Generation Enterprise

Customer Pain Points:The gearbox reservoir suffered from severe fluid contamination, which accelerated mechanical component wear and led to excessively short oil drain intervals.

Equipment / Application:Gearbox Oil Reservoir

Purifier Commissioning Date:2020 to Present

Before Purification

  • ISO Cleanliness Code:23/22/16

  • Operating Status:Fluid contamination exceeded permissible limits, compromising the stability of the cylinder valve speed-governing system.

After Purification

  • After 1 Week:ISO Cleanliness Code: 21/19/16

  • After 3 Weeks:ISO Cleanliness Code: 18/17/14

  • Operating Status:Equipment operates smoothly and reliably with outstanding particulate removal performance.

Keep your oil clean. Keep your business running

Discover how removing particles, water, varnish and acids can reduce breakdowns, extend oil and equipment life, and lower maintenance costs.