Balanced Charge Agglomeration
Positive and negative electrodes are placed in two parallel flow paths through the non-conductive fluid, charging the particulate contaminants — one path with a positive (+) charge and the other with a negative (-) charge.
The oppositely charged particles are then remixed, attract each other and agglomerate into larger clusters, so that fine particles that are otherwise difficult to filter can be easily captured and removed.
| Parameter | Unit | WJL-20 | WJL-30 | WJL-50 | WJL-75 | WJL-100 | WJL-150 | WJL-200 |
|---|---|---|---|---|---|---|---|---|
| Flow Rate | L/min | 20 | 30 | 50 | 75 | 110 | 150 | 200 |
| Working Pressure | MPa | ≤0.5 | ||||||
| Power Supply | V | Customized based on request (For example: USA 480V 60Hz, Mexico 440V/220V 60Hz, Saudi Arabia 380V 60Hz, Nigeria 415V 50Hz...) | ||||||
| Total Power | kW | 0.7 | 1 | 1.8 | 2.3 | 4 | 4.8 | 7 |
| Inlet/Outlet Pipe Size | mm | DN20 | DN25 | DN32 | DN40 | DN40 | DN50 | Inlet DN65, Outlet DN50 |
| Weight | kg | 195 | 260 | 270 | 370 | 400 | 620 | 870 |
| Length | mm | 1040 | 1380 | 1405 | 1600 | 1700 | 2000 | 2500 |
| Width | mm | 530 | 570 | 570 | 820 | 820 | 900 | 900 |
| Height | mm | 1200 | 1215 | 1215 | 1400 | 1600 | 1630 | 1700 |
| Inlet/Outlet Connection | —— | 1CB-30-12WD M30×2 for hose; G3/4"×14 for ball valve | 1CB-36-16WD M36×2 for hose; G1"×11 for ball valve | 1CB-45-20WD M45×2 for hose; G1¼"×11 for ball valve | 1CB-52-24WD M52×2 for hose; G1½"×11 for ball valve | -- -- | ||
Customer Background:A Wind Power Generation Enterprise
Customer Pain Points:The gearbox reservoir suffered from severe fluid contamination, which accelerated mechanical component wear and led to excessively short oil drain intervals.
Equipment / Application:Gearbox Oil Reservoir
Purifier Commissioning Date:2020 to Present
Before Purification
ISO Cleanliness Code:23/22/16
Operating Status:Fluid contamination exceeded permissible limits, compromising the stability of the cylinder valve speed-governing system.
After Purification
After 1 Week:ISO Cleanliness Code: 21/19/16
After 3 Weeks:ISO Cleanliness Code: 18/17/14
Operating Status:Equipment operates smoothly and reliably with outstanding particulate removal performance.
Discover how removing particles, water, varnish and acids can reduce breakdowns, extend oil and equipment life, and lower maintenance costs.